High Conductance Ground EM Plates Modelled at Narryer
Released
Released
Announcement PDF
ASX Release
22nd May 2024
Narryer Project (100% BUX) High Conductance Ground EM
Plates Modelled at Ranger & Oculus Prospects
•
•
•
Ground EM surveys identify three high conductance EM plates
Extremely high conductance of plates indicates presence of either iron
bearing copper/nickel sulphides or graphite
Planning underway for maiden drilling of Ranger Prospect
Buxton Resources Ltd (‘Buxton’; ASX:BUX) is pleased to update shareholders that
results from a second ground Moving Loop Electro-Magnetic (MLEM) survey recently
completed at the Narryer Project have defined several new EM plates with
conductance levels up to 10,000 Siemens (Figure 1, Table 1).
Figure 1: Ranger Prospect EM and geochemistry with HeliTEM2 background image (channel z15). A single line
of MLEM was run at the Oculus Prospect over coincident Ni + Cu in soil samples.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
The recent MLEM survey followed-up nickel & copper soil geochemical anomalies
~2 km south from the Ranger Prospect, where IGO had previously undertaken a
MLEM survey. Soil anomalies at both Ranger and Oculus are subdued by a strong
transported component, and hence metal levels are low. Nevertheless, the Oculus
results represent the most coherent and anomalous nickel and copper levels from
over 400 samples collected to date.
Modelling of the new Oculus Prospect MLEM data has identified two additional
plates with conductance values between 5,000 – 10,000 Siemens (Table 1).
Figure 2: Perspective 3D view showing new MLEM plates, airborne EM channel 15 image and inversion cross
sections along selected flight-lines. The conductivity imagery & MLEM models define a synformal structure at
Oculus. The planned drillholes with PoW approvals & heritage clearances at Ranger are also shown. Heritage
surveying has not been undertaken at the Oculus Prospect.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
Reinterpretation of the 2023 Ranger MLEM survey has defined a 6,000 Siemen plate
only slightly smaller than the plate modelled by IGO at 2,100 Siemens.
Table 1: MLEM Modelling Results (re-interpretation of 2023 Ranger survey plus new line at Oculus)
Locality
Estimated Size of EM Plate
Ranger
Oculus_1
Oculus_2
150 m strike, 800 m down plunge, 195 m depth (to top)
750 m strike, 1000 m down plunge, 100 m depth (to top)
750 m strike, 1000 m down plunge, 100 m depth (to top)
Dip
/
Dip
Direction
-20 / 160
-38 / 274
-54 / 85
Conductance
(Siemens)
6,000
10,000
5,000
The extremely high conductance of the EM models indicates the presence of either
iron (+/- nickel & copper) bearing sulphides or graphite.
Buxton interprets the geological setting at Ranger and Oculus to be similar to the
nickel deposits of the Thompson Nickel Belt in Canada and that the large conductive
synformal feature at Oculus potentially represents an excellent trap for nickel
introduced by small ultramafic intrusions (Figure 3).
Figure 3: Cross sections showing the Thompson Nickel Mine where orebodies lie within hinges and along limbs
of fold structures where Pipe Formation sulfidic meta-sediments have trapped nickel introduced by small, lenslike ultramafic intrusions.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
Buxton has commenced planning a maiden exploration drill program to confirm
presence of Ni-Cu sulfide mineralisation at Ranger. Programme of Work and
Heritage Clearance survey approvals have been received to undertake that work.
Extension Moving Loop EM surveys are now being planned, along with extending
PoW and Heritage approvals to cover the Oculus Prospect.
Buxton looks forward updating shareholders on progress from this exciting project.
---ooo---
This announcement is authorised by the Board of Buxton Resources Ltd.
For further information, please contact:
Martin Moloney
Chief Executive Officer
marty@buxtonresources.com.au
Sam Wright
Company Secretary
sam@buxtonresources.com.au
About the Narryer Project
The Narryer Terrane forms part of the Archean Yilgarn Craton margin which hosts the recently
discovered, world-class Julimar Ni-Cu-PGE Project. This new discovery by Chalice Mining Ltd and the
presence of numerous Ni-Cu-PGE occurrences along a >1,000km strike length defines the West
Yilgarn Ni-Cu-PGE Province - a highly prospective new exploration frontier now subject to intense
exploration activity. Buxton has also now identified that the Narryer Project has potential for
carbonatite-related Rare Earth Element (REE) style deposits in the Proterozoic Badgeradda Basin
rocks which have been accreted to the Yilgarn Craton. The Narryer Project also has potential for
regolith-hosted REE within both Proterozoic and Archean successions.
With the granting of E09/2722, Buxton now holds 1,918 km2 in four granted ELs along the highly
prospective Yilgarn Western Margin, including the adjoining ~30 km long tectonic sliver of the
Proterozoic Badgeradda Basin which has been emplaced here along this craton margin.
During 2021 & 2022, Buxton completed ground reconnaissance, a regionally extensive 1-km spaced
ground gravity survey and a highly targeted 2566.6-line km Airborne EM survey. Interpretation of the
AEM data has identified multiple high priority anomalies, three of which warranted immediate followup by moving loop EM, which was completed at Bandito, Prodigy and Ranger Prospects in early 2023.
Additional soil sampling was conducted over AEM targets in late 2003 which provided
encouragement to extend the Ranger ground EM coverage.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
In additional to well defined Ni-Cu-PGE prospectivity, the broad tectonic and geological setting is
prospective for REE, with the Gascoyne region shaping up as next Australia’s REE hotspot. REE
projects nearby include Yangibana (under construction, ASX: HAS), Mangaroon (ASX: DRE), Mick Well
(ASX: KFM), and Innouendy (ASX: DM1). The only REE operation in production in Australia is Mount
Weld (ASX: LYC), near Laverton, WA.
Figure 4: Narryer Project location map.
Competent Persons
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
The information in this report that relates to Exploration Results is based on information compiled by
Mr Martin Moloney, Member of the Australian Institute of Geoscientists and Society of Economic
Geologist. Mr Moloney is a full-time employee of Buxton Resources Ltd. Mr Moloney has sufficient
experience which is relevant to the activity being undertaken to qualify as a “Competent Person” as
defined in the 2012 edition of the Joint Ore Reserves Committee (JORC) Australasian Code for
Reporting of Exploration Results, Mineral Resources and Ore Reserves. Mr Moloney consent to the
inclusion in this report of the matters based on the information in the form and context in which it
appears.
The information presented herein that relates to Exploration Results from analysis of the Ground
Electromagnetic survey results is based on information compiled and reviewed by the Russell
Mortimer, a Competent Person who is a Member of The Australian Institute of Geoscientists and fairly
represents this information. Mr Mortimer has sufficient experience relevant to the style of
mineralisation and type of deposit under consideration, and to the activities undertaken, to qualify as
a Competent Person as defined in the 2012 Edition of the Joint Ore Reserves Committee (JORC)
Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves. Mr
Mortimer is an independent Consultant Geophysicist at Southern Geoscience Consultants Pty Ltd and
consents to the inclusion in the report of the matters based on his information in the form and context
in which it appears.
Previously Reported Information
There is information in this announcement relating to exploration results previously announced on:
1.
2.
3.
4.
13th October 2022 - High priority AEM anomalies detected at Narryer Project
30th January 2023 - Exploration Update - Narryer Project
2nd August 2023 - Highly Anomalous REE in Rock Chip at Prodigy Prospect
24th August 2023 - Narryer Soil Sampling Program Complete (clarification)
Validity of Referenced Results
Buxton confirms that it is not aware of any new information or data that materially affects the
information from previous ASX announcements which has been referenced in this announcement.
Cautionary Note Regarding Forward-Looking Information
This Announcement contains forward-looking statements and forward-looking information within the
meaning of applicable Australian securities laws, which are based on expectations, estimates and
projections as of the date of publication. This forward-looking information includes, or may be based
upon, without limitation, estimates, forecasts and statements as to management’s expectations with
respect to, among other things, the timing required to execute the Company’s programs, and the
length of time required to obtain permits, certifications and approvals.
Wherever possible, words such as “anticipate”, “believe”, “expect”, “intend”, "should", "intend",
“may” and similar expressions have been used to identify such forward-looking information. Forward-
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
looking information is based on the opinions and estimates of management at the date the
information is given, and on information available to management at such time. Forward-looking
information involves significant risks, uncertainties, assumptions, and other factors that could cause
actual results, performance or achievements to differ materially from the results discussed or implied
in the forward-looking information. These factors, including, but not limited to, fluctuations in
currency markets, fluctuations in commodity prices, the ability of the Company to access sufficient
capital on favourable terms or at all, changes in national and local government legislation, taxation,
controls, regulations, political or economic developments in Australia or other countries in which the
Company does business or may carry on business in the future, operational or technical difficulties in
connection with exploration or development activities, employee relations, the speculative nature of
mineral exploration and development, obtaining necessary licenses and permits, contests over title
to properties, especially title to undeveloped properties, the inherent risks involved in the exploration
and development of mineral properties, the uncertainties involved in interpreting drill results and
other geological data, environmental hazards, industrial accidents, limitations of insurance coverage
and the possibility of project cost overruns or unanticipated costs and expenses, and should be
considered carefully.
Many of these uncertainties and contingencies can affect the Company’s actual results and could
cause actual results to differ materially from those expressed or implied in any forward-looking
statements made by, or on behalf of, the Company. Prospective investors should not place undue
reliance on any forward-looking information. Although the forward-looking information contained on
in this Announcement is based upon what management believes, or believed at the time, to be
reasonable assumptions, the Company cannot assure prospective purchasers that actual results will
be consistent with such forward-looking information, as there may be other factors that cause results
not to be as anticipated, estimated or intended, and neither the Company nor any other person
assumes responsibility for the accuracy and completeness of any such forward-looking information.
The Company does not undertake, and assumes no obligation, to update or revise any such forwardlooking statements or forward-looking information contained herein to reflect new events or
circumstances, except as may be required by law. No stock exchange, regulation services provider,
securities commission or other regulatory authority has approved or disapproved the information
contained in this Announcement.
JORC Table: Section 1 – Sampling Techniques and Data
Criteria
JORC Code explanation
Commentary
Sampling techniques
Nature and quality of sampling (eg cut channels, random
chips, or specific specialised industry standard
measurement tools appropriate to the minerals under
investigation, such as down-hole gamma sondes, or
handheld XRF instruments, etc). These examples should
not be taken as limiting the broad meaning of sampling.
Include reference to measures taken to ensure sample
representivity and the appropriate calibration of any
measurement tools or systems used.
The Ground Electromagnetic (EM) survey was
undertaken by Wireline Services Group using GeoResults
DRTX TX4 high power transmitter (~90 Amps), highly
sensitive EMIT Fluxgate B-field sensors and single-turn
16 mm copper cable. The SMTFluxgate B-field receiver
used an In-loop Position. The moving loop EM used a
200m square loop.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
Drilling techniques
Drill sample recovery
Aspects of the determination of mineralisation that are
Material to the Public Report. In cases where ‘industry
standard’ work has been done this would be relatively
simple (e.g. ‘reverse circulation drilling was used to
obtain 1 m samples from which 3 kg was pulverised to
produce a 30 g charge for fire assay’). In other cases,
more explanation may be required, such as where there is
coarse gold that has inherent sampling problems.
Unusual commodities or mineralisation types (e.g.
submarine nodules) may warrant disclosure of detailed
information.
Drill type (e.g., core, reverse circulation, open-hole
hammer, rotary air blast, auger, Bangka, sonic, etc) and
details (e.g. core diameter, triple or standard tube, depth
of diamond tails, face-sampling bit or other type, whether
core is oriented and if so, by what method, etc).
Soil samples were taken from a shallow & wide hole dug
with a mattock. 250g -4mm sample into paper geochemi
bags using a large aluminium spoon & sieve.
Method of recording and assessing core and chip sample
recoveries and results assessed.
Measures taken to maximise sample recovery and ensure
representative nature of the samples.
Not applicable, the announcement does not pertain to
drill hole results.
Not applicable, the announcement does not pertain to
drill hole results.
Whether a relationship exists between sample recovery
and grade and whether sample bias may have occurred
due to preferential loss/gain of fine/coarse material.
Logging
Whether core and chip samples have been geologically
and geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining studies
and metallurgical studies.
Whether logging is qualitative or quantitative in nature.
Core (or costean, channel, etc) photography.
The total length and percentage of the relevant
intersections logged.
The regolith regime was interpreted by a qualified
geologist for all soil samples.
Sub-sampling
techniques and
sample preparation
If core, whether cut or sawn and whether quarter, half or
all core taken.
If non-core, whether riffled, tube sampled, rotary split,
etc and whether sampled wet or dry.
Entire 4kg samples are submitted to the laboratory for
sample preparation and analysis. Sample sizes are
considered appropriate to the grainsize and
mineralisation observed.
For all sample types, the nature, quality and
appropriateness of the sample preparation technique.
Quality control procedures adopted for all sub-sampling
stages to maximise representivity of samples.
Measures taken to ensure that the sampling is
representative of the in-situ material collected, including
for instance results for field duplicate/second-half
sampling.
Whether sample sizes are appropriate to the grain size of
the material being sampled.
Quality of assay data
and laboratory tests
The nature, quality and appropriateness of the assaying
and laboratory procedures used and whether the
technique is considered partial or total.
Australian Laboratory Services (Perth) – “ALS” prepares
each sample by oven drying the entire sample for 12
hours at 100°C (DRY-21). Samples are then crushed in a
jaw-crusher to 70% passing 6 mm (CRU-21). The entire
sample is then pulverized in LM5 grinding robotic mills
with low Cr-steel pulverising bowls (particle size
distribution (PSD) target of 85% passing 75 m; PUL-23). A
300g master pulp is collected for analysis, with the
remaining “reject” pulp being retained in storage.
ALS laboratories, Perth complete pulveriser size checks
every 50th sample to ensure particle size distribution
compliance as part of routine internal quality procedures
to ensure the target PSD of 85% passing 75 µm is
achieved.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
Laboratory quality control processes include the use of
internal lab standards using certified reference materials
(CRMs) and duplicates. Quality control procedures
involve insertion of certified reference materials, blanks,
and collection of duplicates at the pulverisation stage.
Results were within acceptable limits of certified
reported values. Company CRMs were not used
For geophysical tools, spectrometers, handheld XRF
instruments, etc, the parameters used in determining the
analysis including instrument make and model, reading
times, calibrations factors applied and their derivation,
etc.
Soil samples were analysed using a four-acid digestion,
with ICP-AES finish (ME-ICP61) for Ag, Al, As, Ba, Be, Bi,
Ca, Cd, Co, Cr, Cu, Fe, Ga, K, La, Mg, Mn, Mo, Na, Ni, P,
Pb, S, Sb, Sc, Sr, Th, Ti, Tl, U, V, W, and Zn.
The EM survey was undertaken by Wireline Services
Group using the following key components:
-
Nature of quality control procedures adopted (eg
standards, blanks, duplicates, external laboratory checks)
and whether acceptable levels of accuracy (ie lack of bias)
and precision have been established.
EMIT SMARTem 24 Receiver
EMIT SMARTem Fluxgate
GeoResults DRTX TX4 Transmitter - 100 Amp /
250 Voltage output
EMIT Tx controller
EM data is recorded digitally and displayed live in the
field, enabling operators to review the raw data for live
data quality assessment.
EM data was reviewed daily by an experienced
independent geophysicist.
The field data collection contractor Wireline Services
Group operates under the following accredited systems:
ISO 14001:2015 Environmental Management
Systems
ISO 45001:2018 Occupational Health & Safety
Management Systems
ISO 9001:2008 Quality Management Systems
Verification of
sampling and
assaying
The verification of significant intersections by either
independent or alternative company personnel.
Location of data
points
The use of twinned holes.
Not applicable, the announcement does not pertain to
drill hole results.
Documentation of primary data, data entry procedures,
data verification, data storage (physical and electronic)
protocols.
MLEM data was recorded digitally using EMIT SMARTem
24 Receiver. The digital data was backed-up via email
from the field camp to head office and the consulting
geophysicist.
Discuss any adjustment to assay data.
Accuracy and quality of surveys used to locate drill holes
(collar and down-hole surveys), trenches, mine workings
and other locations used in Mineral Resource estimation.
Specification of the grid system used.
PO Box 661
Nedlands WA 6009
EM data was reviewed daily by an experienced
independent geophysicist.
Not applicable, the announcement does not pertain to
assay intersections.
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
Soil sampling data was recorded onto hardcopy in the
field, with a redundant location record in the GPS
system.
Not applicable for geophysics.
Positional control for the MLEM survey and soil sampling
was via handheld GPS (+/-5m).
All coordinates are based on Map Grid Australia Zone 50,
Geodetic Datum of Australia 1994
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
Quality and adequacy of topographic control.
Data spacing and
distribution
Data spacing for reporting of Exploration Results.
Orientation of data in
relation to geological
structure
Whether the orientation of sampling achieves unbiased
sampling of possible structures and the extent to which
this is known, considering the deposit type.
If the relationship between the drilling orientation and
the orientation of key mineralised structures is considered
to have introduced a sampling bias, this should be
assessed and reported if material.
The measures taken to ensure sample security.
Sample security
Audits or reviews
Whether the data spacing and distribution is sufficient to
establish the degree of geological and grade continuity
appropriate for the Mineral Resource and Ore Reserve
estimation procedure(s) and classifications applied.
Whether sample compositing has been applied.
The results of any audits or reviews of sampling
techniques and data.
The MLEM crew used handheld Garmin GPS units for
topographic control. The estimated accuracy of this
system is 1-2m which his deemed sufficient for this type
of survey.
The MLEM survey consisted of 200m spaced lines with
100m spaced acquisition centres. This survey density is
deemed sufficient by the CPs for first pass exploration
screening of greenfields nickel prospects.
The MLEM survey achieves an unbiased sampling of the
EM field by constantly moving the transmitter loop. The
Oculus MLEM and soil surveys lines were designed to
cross the geological structure at approximately 90
degrees to minimise sampling bias due to geological
structure.
The EM data was maintained on secure servers managed
by WSG and the independent contractor. Final data as
received by Buxton is also stored on a secure network.
Data was reviewed by a independent qualified
geophysicist (CP Russell Mortimer) and determined to
have been collected and processed in a satisfactory
manner.
JORC Table: Section 2 – Reporting of Exploration Results
Criteria
JORC Code explanation
Commentary
Mineral tenement and
land tenure status
Type, reference name/number, location and ownership
including agreements or material issues with third parties
such as joint ventures, partnerships, overriding royalties,
native title interests, historical sites, wilderness or
national park and environmental settings.
BUX have a 100% interest in Live exploration licenses
E09/2427, E09/2428, E09/2429 and E09/2722. No
material issues with land access are known at this stage.
Exploration done by
other parties
Geology
The security of the tenure held at the time of reporting
along with any known impediments to obtaining a licence
to operate in the area.
Acknowledgment and appraisal of exploration by other
parties.
Deposit type, geological setting and style of
mineralisation.
A Subscription Agreement, Option Agreement and EarnIn and Joint Venture Agreement on the Narryer Project
was executed with IGO Limited as detailed in ASX
Announcement 22 October 2022, this agreement expired
on June 19 2023 without IGO Limited taking up their
option on the project.
The tenement is in good standing with DMIRS and there
are no known impediments for exploration on this
tenement.
Numerous exploration parties have held portions of the
area covered by BUX tenure previously. Buxton has
undertaken a detailed review of 140 previous exploration
reports as held in the DMIRS WAMEX system, along with
a compilation of other relevant open file data.
The primary target mineralisation style in the Project
area is interpreted to be primary orthomagmatic
intrusion related Ni-Cu-Co-PGE sulphide type.
The Project covers regions of the Narryer Terrane in the
Yilgarn Craton, which includes reworked remnants of
Archean greenstone sequences and layered maficultramafic complexes that are prospective for intrusionhosted Ni-Cu-(Co)-(PGEs). The Project also covers a sliver
of Badgeradda Basin – a poorly characterised sequence
of volcanics and sedimentary rocks which may be
Neoproterozoic – Mesoproterozoic in age.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
www.buxtonresources.com.au
The Project is situated on the (NW) margin of the Yilgarn
Craton which - a deep-seated structural configuration
that is favourable for the focussing of magmatic
intrusions and related sulphide deposits.
Drill hole Information
A summary of all information material to the
understanding of the exploration results including a
tabulation of the following information for all Material
drill holes:
o easting and northing of the drill hole collar
Not applicable, the announcement does not pertain to
drill hole results.
o elevation or RL (Reduced Level – elevation above sea
level in metres) of the drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
Data aggregation
methods
o hole length
If the exclusion of this information is justified on the basis
that the information is not Material and this exclusion
does not detract from the understanding of the report,
the Competent Person should clearly explain why this is
the case.
In reporting Exploration Results, weighting averaging
techniques, maximum and/or minimum grade truncations
(e.g. cutting of high grades) and cut-off grades are usually
Material and should be stated.
Where aggregate intercepts incorporate short lengths of
high grade results and longer lengths of low grade results,
the procedure used for such aggregation should be stated
and some typical examples of such aggregations should
be shown in detail.
The assumptions used for any reporting of metal
equivalent values should be clearly stated.
Not applicable, the announcement does not pertain to
assay results.
Relationship between
mineralisation widths
and intercept lengths
These relationships are particularly important in the
reporting of Exploration Results.
If the geometry of the mineralisation with respect to the
drill hole angle is known, its nature should be reported.
If it is not known and only the down hole lengths are
reported, there should be a clear statement to this effect
(eg ‘down hole length, true width not known’).
Not applicable, the announcement does not discuss or
postulate thickness or width of mineralisation.
Diagrams
Appropriate maps and sections (with scales) and
tabulations of intercepts should be included for any
significant discovery being reported. These should include,
but not be limited to a plan view of drill hole collar
locations and appropriate sectional views.
Where comprehensive reporting of all Exploration Results
is not practicable, representative reporting of both low
and high grades and/or widths should be practiced to
avoid misleading reporting of Exploration Results.
See text and figures in body of release.
Other substantive
exploration data
Other exploration data, if meaningful and material,
should be reported including (but not limited to):
geological observations; geophysical survey results;
geochemical survey results; bulk samples – size and
method of treatment; metallurgical test results; bulk
density, groundwater, geotechnical and rock
characteristics; potential deleterious or contaminating
substances.
Not applicable.
Further work
The nature and scale of planned further work (e.g. tests
for lateral extensions or depth extensions or large-scale
step-out drilling).
See text and figures in body of release.
Balanced reporting
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
Reporting of BUX’s rock chip is limited areas of outcrop
or subcrop, float samples have been omitted for clarity.
This is not deemed to misrepresent the indicated
prospectivity of the tenement package.
www.buxtonresources.com.au
Diagrams clearly highlighting the areas of possible
extensions, including the main geological interpretations
and future drilling areas, provided this information is not
commercially sensitive.
PO Box 661
Nedlands WA 6009
Suite 1, First Floor
14-16 Rowland Street
Subiaco WA 6008
T. 08-9380 6063
E. info@buxtonresources.com.au
See figures in body of release.
www.buxtonresources.com.au
Share your feedback
Discover